SPADE  DOES  NOT   RAISE   OR   LOWER
BATTERY  AND  GENERATING  SYSTEM

TM-9-2350-238-10 Semi Trailer Tank 5000-Gallon Fuel Dispensing Automotive M969A 2 (NSN 2330-01-377-9337) Manual
Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
TM   9-2350-238-10 Table   3-1.   TROUBLESHOOTING–CONTINUED MALFUNCTION TEST   OR   INSPECTION CORRECTIVE   ACTION LIGHTING   SYSTEM 19.   ALL   LIGHTS   DO   NOT   OPERATE. Step   1. Check   to   see   that   MASTER   switch   (1)   and   instrument   switch   (2)   are   in   ON position. Set   switches   to   ON   position. Step   2. Check   to   see   that   individual   switch   is   ON. Set   switch   to   ON   position. 20.   DRIVING   LIGHTS   DO   NOT   OPERATE. Step   1. Check   for   loose   wiring   connections   at   vehicle   light   switch. Tighten   or   connect   loose   connections. Step   2.   Check   for   open   light   circuit   breaker. If   breaker   does   not   reset   within   30   seconds,   or   if   circuit   breaker repeatedly   closes   and   opens,   notify   unit   maintenance   personnel. 21.   DRIVING   LIGHTS   BURN   DIMLY. Step   1. Check   to   see   if   batteries   are   discharged. See   if   battery   indicator   reads   in   red   band.   If   batteries   are   discharged, notify   unit   maintenance   personnel. Step   2.   Check   to   see   if   battery   cable   connections   are   loose   or   corroded. If   corroded   or   loose,   notify   unit   maintenance   personnel. 3 - 19