SECTION V: TROUBLESHOOTING
TM 9-2350-256-20
WARNING
Remove all jewelry such as rings, dog
tags, bracelets, etc. If jewelry contacts
a metal surface a direct short may result
in instant heating of tools, damage to
equipment, and injury or death to
personnel.
R Remove four screws (1) and four lockwashers (2), and
release electrical accessories panel (3). Ground panel.
Reconnect electrical accessories panel wiring harness
to electrical accessories panel. Disconnect wire 1 (from
socket D) from generator cutout switch. Place red lead
of multimeter in wire 1 and black lead to ground. Turn
MASTER switch on and check for voltage. Turn
MASTER switch OFF. If voltage is present, go to step
S. If voltage is not present repair/replace wire 1 of bilge
pump main power wiring harness from socket D (see
paragraph 6-84).
S Reconnect wire 1 (from socket D) to generator cutout
switch. Disconnect wire 1 (from socket C) from
generator cutout switch. Place red lead of multimeter
on generator cutout switch and black lead to ground.
Turn MASTER switch on, open generator cutout switch
and check for voltage. Turn MASTER switch OFF,
close generator cutout switch. If voltage is present,
repair/replace wire 1 of bilge pump main power wiring
harness (see paragraph 6-84). If voltage is not present,
replace generator cutout switch (see paragraph 6-9).
2-137