SECTION VI: MISCELLANEOUS ELECTRICAL COMPONENTS
TM 9-2350-256-20
6-104 REPLACE DUMMY CONNECTOR ASSEMBLY (INFRARED AND PASSIVE NIGHT VIEWER)
THIS TASK COVERS
a. Removal
b. Installation
INITIAL SET-UP
Tools:
Equipment Condition:
Tool kit, general mechanic's (Appendix C, item 53)
Infrared and passive night viewer connector
disconnected (see paragraph 6-15)
Parts:
Lockwashers (4) (Appendix G, item 102)
a. REMOVAL
Remove dummy connector (1) by removing four screws (2)
and four lockwashers (3).
b. INSTALLATION
Install dummy connector (1) using four new lockwashers (3)
and four screws (2).
NOTE
Follow-on maintenance:
Connect infrared and
passive night viewer
connector (see
paragraph 6-15)
6-105 REPLACE/REPAIR ELECTRICAL KIT FOR M239 SMOKE GRENADE LAUNCHER DISCHARGER FEED
THROUGH CABLE ASSEMBLIES (11672298-1 AND 11672298-21
THIS TASK COVERS
a. Removal
b. Installation
INITIAL SET-UP
Tools:
Equipment Condition:
Tool kit, general mechanic's (Appendix C, item 53)
Discharger removed (see paragraph 15-2)
Soldering gun (Appendix C, item 50)
WARNING
Be certain MASTER switch is OFF when working on electrical systems to avoid electrical shock or burns.
Connector No.
Electrical Lead To:
Wire No.
1
Smoke grenade launcher system wiring harness
2
Smoke grenade launcher tubes
6-261