CHAPTER 9: MAINTENANCE OF HULL- AND CAB-RELATED COMPONENTS
TM 9-2350-256-20
9-32 REPLACE LEFT AND RIGHT STOWAGE COMPARTMENT DOORS-Continued
b.
INSTALLATION
1
If removed, install flow regulator setting instruction plate (11) with four new rivets (12).
2
Install stowage compartment door (7) with two straight pins (10), two washers (9), and two new cotter pins (8).
3
Install new rubber strip (6) by applying adhesive and pressing strip in place. Allow adhesive to dry before
closing stowage compartment door (7).
4
Install handle (1) with latch (5), washer (4), nut (3), and new cotter pin (2).
9-56