e. Adjustable Flow Hydraulic Regulator. The deck grilles 3 and 4 (fig. 2-2). Remove and install the
hydraulic lines to be disconnected from the ad- adjustable flow hydraulic regulator as shown in
justable flow hydraulic regulator are located under figure 2-46.
Figure 2-46. Adjustable flow hydraulic regulator- removal and installation.
f. Spade Subplate and Control Valve Assem-
sub plate assembly from the vehicle. Remove and
bly. The spade control valve can be removed from
install the spade subplate and valve assembly or the
the subplate and replaced without removing the
spade control valve only as shown in figure 2-47.
2-80