TM 9--2350--292--10
OPERATE EXHAUST SMOKE GENERATING SYSTEM -- CONTINUED
0069 00
7. Activate smoke generating system by opening either operators (4) or commanders (5) VEHICLE EXHAUST
SMOKE switch guard and moving switch to ON position. The indicator (6) will light when system is activated.
8. To turn off the smoke generator, close the operators (4) or commanders (5) switch guard on the VEHICLE
EXHAUST SMOKE switch; this will move switch to OFF position. Open engine deck grille door (WP 0033 00),
close manual fuel shutoff handle and install new lockwire.
9. Engine must run for at least 5 minutes to clear exhaust before main engine can be shut down and MASTER
switch (3) turned OFF.
5
3
6
4
END OF TASK
0069 00--3/4 blank