TM 9--2350--292--10
0101 00--60
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
0101 00
TABLE 4 PREVENTIVE MAINTENANCE CHECKS AND SERVICES, WEEKLY--CONTINUED
Item No.
Not Fully Mission
Capable If:
CREWMEMBER
Procedure
LOCATION
Item to Check/
Service
Interval
CREW
COMPARTMENT
DRIVER
WARNING
13
Weekly
Gas Particulate
Filtration Unit
(GPFU)
a. Turn switch to ON. Check motor for
smooth operation and check outlets for air
flow (WP 0065 00).
b. Check cable assembly for worn or
cracked insulation and loose connections.
c. Check all hoses for wear, damage or
deterioration.
d. Check entire filter unit assembly for
dents, cracks, or missing parts.
e. Turn M3 heater switch to ON. Check
for heated air at air flow outlets.
NOTE
M3 heater must operate 10--15 minutes be-
fore heat is felt.
f. Check protective mask in accordance
with TM 3--4240--280--10.
Does not operate or
no air flow.
END OF TASK