TM 9--2350--292--20--1
0270 00--2
MASTER POWER CIRCUIT BREAKER REPLACEMENT -- CONTINUED
0270 00
Installation
1. Install circuit breaker (3) with two screws (4) and two new lockwashers (5).
2. Connect wiring harness 3W218 wire 400/459B (2) and wiring harness 3W142 wire 400/459B (1) to circuit breaker (3).
Figure 102
4
5
3
2
1
NOTE
FOLLOW--ON MAINTENANCE:
Connect battery power (WP 0256 00)
END OF TASK