TM 9--2350--292--20--1
0296 00--2
LEAD ASSEMBLY 3W174 REPLACEMENT -- CONTINUED
0296 00
Installation
1. Connect lead assembly 3W174 (4) to master relay terminal mounting bracket (9) with screw (6), new lockwasher
(7) and flat washer (8).
2. Connect lead assembly 3W174 (4) to master relay terminal X2 (5) with screw (1), new spring tension washer (2)
and flat washer (3).
1
2
3
4
5
6
7
8
4
9
NOTE
FOLLOW--ON MAINTENANCE:
Install master relay cover (WP 0271 00)
Connect battery power (WP 0256 00)