TM 9--2350--292--20--1
ENGINE CRANKS SLOWLY BUT WILL NOT START -- CONTINUED
0044 00
Perform battery test (WP 0187 00)
no
yes
Are batteries serviceable?
CONTINUED FROM STEP E
Recharge or replace batteries
as necessary
(WP 0187 00/WP 0288 00).
Verify fault is corrected.
Perform STE--ICE--R test 70
(TM 9--4910--571--12&P) and record results.
no
yes
F
Is VTM reading at least 18 V dc?
G
Perform STE--ICE--R test 71
(TM 9--4910--571--12&P) and record results.
Is VTM reading between 200 and 900 amps?
no
yes
H
Perform tests 67 and 69
using function 02
(TM 9--4910--571--12&P).
If tests are passed, replace
starter (WP 0240 00). Verify
fault is corrected.
Replace starter (WP
0240 00). Verify fault
is corrected.
Troubleshoot starter
protect module (WP
0041 00) Step Z.
CONTINUED FROM STEP A
END OF TASK