TM 9--2350--292--20--1
MOTOR DOES NOT OPERATE -- CONTINUED
0079 00
no
yes
Repair (WP 0290 00) or
replace (WP 0706 00)
lead(s) to purifier(s).
Verify fault is corrected.
E 1. Reconnect leads to purifier switches.
2. Disconnect leads from switches to purifiers at
purifiers.
3. Turn MASTER switch ON
(TM 9--2350--292--10).
4. Place multimeter red lead in each lead
connector to purifiers (one at a time) while
holding black lead to ground. Check for voltage.
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present at both connectors?
CONTINUED FROM STEP D
Replace purifier (WP
0706 00). Verify fault
is corrected.
END OF TASK
0079 00--3/4 blank