TM 9--2350--292--20--1
0082 00--10
ENGINE BATT/GEN GAUGE READS IN YELLOW OR LOWER RED REGION
WITH MAIN ENGINE RUNNING -- CONTINUED
0082 00
CONTINUED FROM STEP AA
CONTINUED ON NEXT PAGE
AB
1. Reconnect harness 3W180 P1 to voltage
regulator.
2. Place one multimeter lead in harness 3W143
P1 socket S and other lead to vehicle ground.
Check for continuity.
Is continuity present?
no
yes
Repair (WP 0290 00) or
replace (WP 0336 00)
ground lead. Verify fault
is corrected.
1. Remove powerpack (WP 0188 00).
2. Install ground hop kit (WP 0189 00).
3. Start engine (TM 9--2350--292--10).
4. Place multimeter red lead on generator terminal
B+ and black lead to ground. Check for voltage.
5. Shut engine down (TM 9--2350--292--10).
Is 28 V dc present?
no
yes
Repair (WP 0290 00) or
replace (WP 0240 00)
lead from terminal B+ to
terminal B at engine
starter. Verify fault is
corrected.
AC