TM 9--2350--292--20--1
0109 00--2
DOME LIGHT FAILS TO OPERATE -- CONTINUED
0109 00
CONTINUED FROM STEP B
C
1. Disconnect lead 38 from dome light.
2. Turn MASTER switch ON
(TM 9--2350--292--10).
3. Place multimeter red lead in lead 38
connector socket and black lead to ground.
Check for voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present?
Repair (WP 0290 00) or
replace (WP 0317 00,
WP 0327 00) harness
4W105 (4W153). Verify
fault is corrected.
no
yes
Replace switch
(WP 0283 00). Verify
fault is corrected.
END OF TASK