TM 9--2350--292--20--1
0117 00--2
STOPLIGHTS FAIL TO OPERATE -- CONTINUED
0117 00
no
yes
Repair (WP 0290 00) or
replace (WP 0314 00)
harness 4W100. Verify fault is
corrected.
CONTINUED ON NEXT PAGE
1. Remove switch panel from bracket
(WP 0242 00) and reconnect ground strap to
switch panel.
2. Disconnect harness 4W105 P1 from switch
panel.
3. Turn MASTER switch ON
(TM 9--2350--292--10).
4. Place multimeter red lead on harness 4W105
P1 socket N and black lead to ground. Check
for voltage.
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present?
CONTINUED FROM STEP B
1. Disconnect harness 4W127 P1 from directional
signal control assembly.
2. Turn MASTER switch ON and turn main light
switch to STOPLIGHT position
(TM 9--2350--292--10).
3. Place multimeter red lead in harness 4W127
P1 socket D and black lead to ground. Check
for voltage.
4. Turn MASTER switch OFF
(TM 9--2350--292--10).
no
yes
Go to Step J.
C
Is 24 V dc present?
D