TM 9--2350--292--20--1
0119 00--3
BLACKOUT STOPLIGHTS FAIL TO OPERATE -- CONTINUED
0119 00
no
yes
Repair (WP 0290 00) or
replace (WP 0314 00)
harness 4W100. Verify
fault is corrected.
D
1. Remove switch panel from bracket
(WP 0242 00) and reconnect ground strap to
switch panel.
2. Disconnect harness 4W105 P1 from switch
panel.
3. Turn MASTER switch ON
(TM 9--2350--292--10).
4. Place multimeter red lead in harness 4W105
P1 socket N and black lead to ground. Check
for voltage.
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Is 24 V dc present?
no
yes
Repair (WP 0290 00) or
replace (WP 0242 00)
harness 4W151. Verify
fault is corrected.
E
1. Disconnect harness 4W151 P1 from switch
S8.
2. Place one multimeter lead on harness 4W151
J4 pin N and other lead in harness 4W151 P1
socket F. Check for continuity.
Is continuity present?
CONTINUED FROM STEP C
CONTINUED ON NEXT PAGE