GRENADE LAUNCHER FAILS TO OPERATE PROPERLY. SOME OR ALL
TUBES FAIL TO OPERATE. ALL OTHER SYSTEMS OPERATE PROPERLY --
CONTINUED
0152 00
L
Is continuity present at both checks?
CONTINUED FROM STEP K
Place one multimeter lead on each launcher
receptacle pin B (one at a time) and other lead
to ground. Check for continuity.
yes
no
Replace faulty launcher
ground lead
(TM 9--1055--642--20&P).
Verify fault is corrected.
Repair or replace firing
tip lead in launcher
(TM 9--1055--642--20&P).
Verify fault is corrected.
END OF TASK