TM 9--2350--292--20--1
0182 00--4
MAIN WINCH FAILS TO SHUT DOWN DURING MALFUNCTION --
CONTINUED
0182 00
G
Is 24 V dc present at both checks?
CONTINUED FROM STEP D
no
yes
1. Remove subfloor plate 18 (WP 0454 00).
2. Disconnect harness 2W612 connectors P1 and
P2 from main winch power reduction manifold.
3. Turn MASTER switch ON and hold WINCH
TEST switch in the TEST position
(TM 9--2350--292--10).
4. Place multimeter red lead on harness 2W612
connectors P1 and P2 socket 1 (one at a time)
and black lead to ground. Check for voltage.
5. Turn MASTER switch OFF
(TM 9--2350--292--10).
Repair (WP 0290 00) or
replace (WP 0292 01)
harness 2W612. Verify
fault is corrected.
H
Is continuity present at both checks?
no
yes
Place one multimeter lead on wiring harness
2W612 connectors P1 and P2 socket 2 (one at a
time) and other lead to ground. Check continuity.
Repair (WP 0290 00)
or replace wiring
harness 2W612
(WP 0292 01). Verify
fault is corrected.
Replace main winch
power reduction man-
ifold (WP 0557 00).
Verify fault is cor-
rected.
FORWARD
END OF TASK