TM 9--2350--292--20--1
0183 00--7
MAIN WINCH FAILS TO SHUT DOWN WHEN WINCH TEST SWITCH IS HELD
IN TEST POSITION -- CONTINUED
0183 00
CONTINUED FROM STEP M
CONTINUED ON NEXT PAGE
N
Is continuity present?
no
yes
Place one multimeter lead on terminal junction T21
terminal B and other lead on winch warning relay
K1 terminal XI. Check for continuity.
Repair (WP 0290 00) or
replace (WP 0244 00)
lead 359B from terminal
junction T21 to relay K1.
Verify fault is corrected.
O
Is continuity present?
no
yes
Place one multimeter lead on relay K1 terminal X2
and other lead on terminal junction T32 terminal C.
Check for continuity.
Replace ground lead
from relay K1 to termi-
nal junction T32
(WP 0244 00). Verify
fault is corrected.
Replace relay K1
(WP 0244 00). Verify
fault is corrected.