TM 9--2350--292--20--1
0187 00--18
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, HOURLY OR ON--CONDITION -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
HOURLY (H) OR
ON--CONDITION
(OC)
BATTERY OR
ENGINE
COMPARTMENT
3
100 H
Auxiliary Power
Unit Crankcase
Oil Change
(HATZ) --
Continued
LUBRICANTS/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
OIL:
Lubricating
Oil, OE/HDO
MIL--L--2104 or
OEA MIL--L--46167
3.17 qt
(3 L)
15 W40 or
OE/HDO--30
(0--237)
OE/HDO--10
(0--237)
OEA
(0--183)
*For Arctic Operation, refer to FM 9--207
h. Fill crankcase with proper grade of oil.
i. Remove saber gauge (7) and check that
oil level reaches FULL mark. If
required, add additional oil.
j. Insert saber gauge (7) and oil filler cap
(4).
k. Start APU and operate for three to five
minutes (TM 9--2350--292--10).
4
7