TM 9--2350--292--20--1
0187 00--41
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, HOURLY OR ON--CONDITION -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
HOURLY (H) OR
ON--CONDITION
(OC)
INTERIOR
8
OC
Hydraulic
Reservoir Fluid
Change --
Continued
LUBRICANTS/
COMPONENTS
REFILL
CAPACITY
EXPECTED TEMPERATURE*
+40°F to --10°F
(+4°C to --23°C)
Above +32°F
(Above 0°C)
0°F to --65°F
(--17°C to --54°C)
Oil: Fire Retardant
Hydraulic Oil
MIL--H--46170
80 gal
(302.80 L)
*For Arctic Operation, refer to FM 9--207
ALL TEMPERATURES (H--544)
j. Fill hydraulic reservoir with proper grade
oil until it reads above DANGER mark on
bayonet gauge (7).
k. Start engine and operate hydraulic
system until oil reaches operating
temperature (TM 9--2350--292--10).
l. Shut down engine
(TM 9--2350--292--10).
m. Remove, wipe clean, then re--insert
bayonet gauge (7). Then remove bayonet
gauge (7) and verify oil level is at lower
FULL mark with boom down or upper FULL
mark with boom up. If required, add
additional oil to bring level to FULL mark.
n. Install hydraulic fill cap (5) and bayonet
gauge (7).
5
7
BOOM UP FULL HOT BOOM DOWN
DANGER