TM 9--2350--292--20--1
0187 00--107
0187 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDING
LUBRICATION INSTRUCTIONS -- CONTINUED
TABLE 3 PREVENTIVE MAINTENANCE CHECKS AND SERVICES
INCLUDING LUBRICATION INSTRUCTIONS, SEMIANNUALLY -- CONTINUED
ITEM
NO.
NOT FULLY
MISSION
CAPABLE
IF:
PROCEDURE
LOCATION
ITEM TO
CHECK/
SERVICE
INTERVAL
SEMIANNUALLY
INTERIOR
20
Gas Particulate
Filter Units and
M3 Air Heaters
WARNING
a. Inspect gas particulate filter units (1)
and M3 air heaters (2) for dents, loose
connections and missing parts.
b. Inspect hose assemblies (3) for loose
or missing mounting hardware, damage
and deterioration.
c. Inspect cable assemblies (4) for
loose connections, damaged insulation
and broken or damaged terminals.
Gas
particulate
filter does not
operate.
M3 heater
produces
heat before
10 minutes of
operation,
FORWARD
3
3
NOTE
M3 heaters must operate for
10--15 minutes before warm air
is felt at stations.
d. Operate gas particulate filter units (1)
and M3 air heaters (2)
(TM 9--2350--292--10).
e. Check air flow at each station.
f. Check for warm air at each station.
g. Shut off gas particulate filter units (1)
and turn M3 air heaters (2) switch to off
(TM 9--2350--292--10).
does not
produce heat
at all stations,
any
damaged,
worn or
missing
components.
4
4
2
4
1
3
3
3
4