TM 9--2350--292--20--2
0620 00--6
AUXILIARY POWER UNIT DUCTING REPLACEMENT -- CONTINUED
0620 00
Installation--Continued
NOTE
The remaining steps are performed with engine deck access
door adjacent to the APU closed (TM 9--2350--292--10).
4. Install elbow (37) and new gasket (40) with four screws (38) and four new lockwashers (39).
5. Slide clamps (34 and 36) over hose (35) and install hose (35) on elbow (37). Position clamp (36) to hold hose
(35) on elbow (37) and tighten clamp (36).
6. Install tube (33) in the other end of hose (35). Position clamp (34) to hold hose (35) on tube (33) and tighten
clamp (34).
7. Slide clamps (30 and 32) over hose (31) and install hose (31) on tube (33). Position clamp (32) to hold hose (31)
on tube (33) and tighten clamp (32).
8. Install tube (29) in the other end of hose (31). Position clamp (30) to hold hose (31) on tube (29) and tighten
clamp (30).
9. Slide clamps (25 and 28) over hose (27) and install hose (27) on tube (29). Position clamp (28) to hold hose (27)
on tube (29) and tighten clamp (28).
10. Install hose (27) over air cleaner adapter (26). Position clamp (25) to hold hose (27) on adapter (26) and tighten
clamp (25).
Figure 340
40
37
39
38
36
35
34
33
26
25
27
28
29
30
31
32