TM 9--2350--292--20--2
0640 00--4
AUXILIARY POWER UNIT RELAY AND MOUNTING BRACKET
REPLACEMENT -- CONTINUED
0640 00
Installation--Continued
5. Install lead assembly 3W727 (9) on relay terminal X2 (10) with screw (6), new springwasher (7) and flat washer
(8).
6. Install wiring harness 3W711 wire 65 (4) on relay terminal X1 (5) with screw (1), new springwasher (2) and flat
washer (3).
Figure 345
1
2
3
5
4
6
7
8
9
10
NOTE
FOLLOW--ON MAINTENANCE:
Install APU into vehicle (WP 0586 00)
END OF TASK