TM 9--2350--292--20--2
0668 00--2
BILGE PUMP BRACKET AND INLET FLANGE REPLACEMENT --
CONTINUED
0668 00
Installation
1. Install bracket (8) on three studs (9) with three new lockwashers (7) and three nuts (6).
2. Remove four screws (1), four lockwashers (2) and impeller housing (4). Discard lockwashers.
3. Install impeller housing (4) and inlet flange (3) to front end bell (5) with four screws (1) and four new lockwashers
(2).
Figure 357
5
4
3
1
2
9
6
7
8
NOTE
FOLLOW--ON MAINTENANCE:
Return bilge pump assembly to deep water fording kit
(WP 0667 00)
END OF TASK