TM 9--2350--292--20--2
0671 00--4
SMOKE GRENADE LAUNCHER ARMING SWITCH BOX AND LAMP
ASSEMBLY REPAIR -- CONTINUED
0671 00
Assembly
1. Install retaining strap (29), new lockwasher (28) and bondnut (27) on lamp assembly (7).
2. Install new gasket (26) and lamp (25) in lamp assembly (7).
3. Install instruction plate (24) on switch box assembly (2) with four new drive screws (23).
4. Install toggle switch (17) and guard (22) in switch box assembly (2) with two screws (21).
5. Install wiring harness 4W150 connector J1 (14) in switch box assembly (2) with four screws (12) and four new
lockwashers (13).
6. Install wire 4W150 GND (20) with screw (18) and two new lockwashers (19).
7. Connect two wires 4W150 SW (15 and 16) to toggle switch (17).