Installation
NOTE
Apply a thin even coat of clean lubricant to all preformed
packings prior to installation.
1. Install three new preformed packings (33, 34 and 35) on hose (29) and preformed packing (32) on tee (30).
2. Install tee (30) in hydraulic pump (24) port X1.
3. Install hose (31) on tee (30).
4. Install hose (29) on transducer 4MT528 (28) then install transducer 4MT528 (28) with hose (29) on tee (30).
5. Install wiring harness 4W503 connector P10 (27) on transducer 4MT528 (28).