Assembly
1. Lubricate cable assembly (10) with graphite.
2. Connect adapter (37) onto pulley (41).
3. Thread and connect cable assembly (10) through pulleys (34, 40, 41 and 42), four conduits (11, 19, 38 and 39)
and dual pull mechanism (32).
4. Insert three cable assembly ends (10) in cable clamp (43).
5. Squeeze cable clamp (43) tightly along its entire length.
6. Grasp both ends of cable clamp (43) at each end approximately 0.18 in. (0.46 cm).
7. Rotate the ends of cable clamp (43) in opposite directions simultaneously until cable clamp has been twisted to
one and one--half turns.
8. Cut short ends of cable (10) to within 0.06--0.25 in. (0.15--0.64 cm) of cable clamp (43).
Figure 369
GRASP CABLE CLAMP
ENDS 0.18 (0.46cm)
CUT CABLE AT CLAMP END
0.06--0.25 (0.15--0.64cm)
34
39
40
10
37
41
38
32
43
10
42
11
10
10
43
10
10
43
10
10
19