TM 9--2350--292--20--2
0699 00--8
FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --
CONTINUED
0699 00
Assembly--Continued
NOTE
Splice is positioned inside dual pull mechanism by pulling
on ends of cable assembly.
15. Position splice (44) against dual side of dual pull mechanism (32). Thread cable assembly (10) through socket
(28) and install plug (27), leaving two inches (5.08 cm) of free cable between pulley release mechanism (22) and
cable fastener assembly (26).
16. Hold cable fastener assembly (26), install exterior cable handle (25).
17. Thread cable assembly (10) through adapter (20), connect conduit (19).
18. Thread cable assembly (10) through socket (18) and install plug (17), leaving two inches (5.08 cm) of free cable
between adapter (20) and cable fastener assembly (16).
19. Hold cable fastener assembly (16), install interior cable handle (15).
20. Position splice (44) against single side of dual pull mechanism (32).
21. Verify cable handles (15 and 25) are in correct position.
Figure 369
INTERIOR
EXTERIOR
SINGLE
SIDE
DUAL
SIDE
19
20
22
32
10
28
27
26
25
32
15
17
18
10
16
44