TM 9--2350--292--20--2
0699 00--9
FIXED FIRE EXTINGUISHER ACTUATOR CABLE ASSEMBLY REPAIR --
CONTINUED
0699 00
Assembly--Continued
22. Thread cable assembly (10) through valve body (8), connect conduit (11).
23. Insert end of cable assembly (10) into slot (45) in cable reel (7). Adjust cable length for five inches (12.7 cm) of
free cable between point A where cable assembly (10) enters cavity of control valve body (8) and point B where
cable enters slot (45) in cable reel (7). Secure cable assembly (10) with two set screws (9).
NOTE
Control valve must be removed from cylinder assembly to
check for correct actuator cable assembly installation.
24. Disconnect tube assembly (46) from adapter (47).
25. Disconnect hose assembly (48) from valve body (8).
26. Position cable reel (7) in valve body (8). Cam side must be down. Top of actuator pin (49) must contact cam sur-
face. Align set arrow on reel with set line on body.
Figure 371
B
A
2
8
47
46
7
48
7
10
49
11
10
9
45
9