TM 9--2350--292--20--2
0428 00--2
HOIST WINCH CABLE ACCESS DOOR AND SEAL REPLACEMENT --
CONTINUED
0428 00
Installation
WARNING
1. Clean seal mating surface on hull with dry--cleaning solvent.
2. Apply rubber based adhesive to new nonmetallic seal (10) and seal mating surface on hull.
3. Install nonmetallic seal (10) on hull.
4. Install two bolts (9) on hull with two new spring pins (8).
5. Install access door (4) on hull with pin (7), flat washer (6) and new cotter pin (5).
6. Secure access door (4) to hull with two flat washers (3), two new lockwashers (2) and two nuts (1).
Figure 206
1
2
3
4
5
6
7
8
9
10
SEAL MATING
SURFACE
END OF TASK