TM 9--2350--292--20--2
HYDRAULIC FILTER MANIFOLD CHECK VALVE AND PRESSURE SENSING
VALVE REPLACEMENT -- CONTINUED
0551 00
Installation
WARNING
1. Apply a light coat of lubricant on five new preformed packings (2 and 6) and five new packing retainers (3 and 7).
2. Install check valve (1) with two new preformed packings (2) and new packing retainer (3) in filter manifold (4).
3. Install pressure sensing valve (5) with three new preformed packings (6) and four new packing retainers (7) in fil-
ter manifold (4).
Figure 300
1
2
3
6
6
6
5
7
7
4
NOTE
FOLLOW--ON MAINTENANCE:
Install subfloor plate #22 (WP 0454 00
Start engine, pressurize hydraulic system
(TM 9--2350--292--10)
Lock spade (TM 9--2350--292--10)
END OF TASK
0551 00--3/4 blank