WARNINGTM 9-2350-238-34-13 Connect 0 to 10 psi (0 to 69 kPa) pressure gage (4), pressure regulator valve (5), and shutoffvalve (6) to hose (3). Connect shutoff valve to compressed air source (7).4 Set pressure regulator valve (5) to 3 psi (21 kPa). Pressurize fabric fuel cell for 5 minutesm i n i m u m . O b s e r v e g a g e f o r a n y p r e s s u r e d r o p .5 C h e c k f o r a i r l e a k a g e w i t h s o a p s o l u t i o n a t t h e f o l l o w i n g p l a c e s:a .a c c e s s c o v e r s.b . f u e l l e v e l t r a n s m i t t e r.c . f u e l f i l l e r n e c k.d . f u e l d r a i n p l u g s .e .coolant heater fuel intake.f. f u e l s u p p l y a n d r e t u r n l i n e q u i c k d i s c o n n e c t s .6 T i g h t e n c a p s c r e w s , i f r e q u i r e d , t o s t o p l e a k s . N o l e a k a g e i s p e r m i s s i b l e . I f l e a k a g e c a n n o t bestopped by tightening capscrews, disassemble the fabric fuel cell to the extent necessary tor e s e a l l e a k i n g a r e a .Failure to reduce pressure to zero before removingi n j u r y .fuel filler neck cap may cause7 R e d u c e f a b r i c f u e l c e l l p r e s s u r e t o z e r o a n d r e m o v e t e s t e q u i p m e n t . I n s t a l l p l u g i n c o o l a ntheater fuel intake (1).8 R e m o v e f u e l f i l l e r n e c k c a p a n d t u r n c a p v e n t v a l v e t o O P E N p o s i t i o n . I n s t a l l f u e l f i l l e r n e ckc a p .9 I n s t a l l r i g h t t u n n e l a c c e s s c o v e r.1 0 Allow 6 hours minimum drying time for sealants, then fill fabric fuel cell with diesel fuel.2-67
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business