CORRECTIVE ACTION Continued
pump still does not operate, notify Direct Support Maintenance. If main hydraulic pump operates but
is noisy or fails to develop sufficient pressure and no additional shaft coupling damage is present, go to
step 6.
WARNING
Solvents can burn easily, give off harmful vapors, and are harmful to skin and clothing. To avoid injury
or death, keep away from open flame and use in a well-ventilated area. If solvent gets on skin or clothing,
wash immediately with soap and water.
WARNING
Particles blown by compressed air can be dangerous. Be certain to direct air stream away from user and
other personnel in the area. Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa).
Use only with effective chip-guarding and personal protective equipment (goggle/shield and gloves).
6.
Remove center rear floor plate (see WP 0303 00). Remove eight socket head screws and remove
hydraulic oil filter cover and oil filter element (see WP 0418 00). Clean hydraulic oil filter element
with cleaning compound (item 9, WP 0489 00) and dry with compressed air. Replace filter element
and cover. If problem persists notify Direct Support Maintenance.
END OF WORK PACKAGE