TM 9-2350-256-20-1
0056 00
CORRECTIVE ACTION Continued
19. Disconnect bulkhead to APU, master relay, and rigger's lights wiring harness from APU engine
disconnect. Place red lead of multimeter in socket F of wire 61 and black lead to ground. Turn
MASTER, APU pressure and APU GEN switches ON and check for voltage. Turn MASTER, APU
pressure and APU GEN switches OFF. If voltage is present, notify Direct Support Maintenance. If
voltage is not present, repair/replace wire 61 of bulkhead to APU, master relay, and rigger's lights
wiring harness (see WP 0224 00).
END OF WORK PACKAGE