TM 9-2350-256-20-1
0061 00
CORRECTIVE ACTION Continued
7.
Reconnect wire 419 to panel connector side of 15 A circuit breaker. Disconnect wire 419 from APU
FUEL SHUTOFF switch side of 15 A circuit breaker. Place red lead of multimeter on terminal of circuit
breaker and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER
switch OFF. If voltage is present, go to step 8. If voltage is not present, replace 15 A circuit breaker
(see WP 0438 00).
8.
Reconnect wire 419 to APU FUEL SHUTOFF switch side of 15 A circuit breaker. Disconnect wire
419 from circuit breaker side of APU FUEL SHUTOFF switch. Place red lead of multimeter in wire
419 and black lead to ground. Turn MASTER switch on and check for voltage. Turn MASTER switch
OFF. If voltage is present, go to step 9. If voltage is not present, repair/replace wire 419 of APU fuel
shutoff lead assembly (see WP 0438 00).
0061 00-6