TM 9-2350-256-20-2
0168 00
Removal
1.
Disconnect connector (1) from thermostatic switch (2). Unscrew and remove thermostatic switch.
2.
Disconnect connector (3) from temperature transmitter (4). Unscrew and remove temperature transmitter.
3.
Disconnect connector (5) from pressure transmitter (6). Unscrew and remove pressure transmitter.
Installation
1.
Install pressure transmitter (6) and connect connector (5).
2.
Install temperature transmitter (4) and connect connector (3).
3.
Install thermostatic switch (2) and connect connector (1).
NOTE
Follow-on maintenance: Install powerplant (see WP 0098 00).
END OF WORK PACKAGE