TM 9-2350-256-20-2
0196 00
12. Disconnect connectors (13 and 14) from switch panel, radio, and bilge pump to bulkhead wiring harness (28).
Disassembly
1.
Disassemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Assembly
1.
Assemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Installation
1.
Connect connectors (13 and 14) to switch panel, radio, and bilge pump to bulkhead wiring harness (28).
2.
Connect connectors (11 and 12) to switch panel to neutral safety switch to bulkhead wiring harness (29).
3.
Connect connectors (10) to switch panel, radio, and bilge pump to bulkhead wiring harness (28).
4.
Connect connector (9) to bilge pump lead relay wiring harness (27).
5.
Connect connectors (8) to winch illumination lamp assembly (26).
6.
Install ground lead (7) to hull (23) using lockwasher (25) and screw (24).
7.
Connect connector (6) to troublelight assembly (22).
8.
Connect connector (5) to rigger's fixed spotlight (21).
9.
Connect connector (4) to ventilator blower (20).
0196 00-5