TM 9-2350-256-20-2
0204 00
Removal
1.
Remove 11 clamps (21) by removing screw (22) and lockwasher (23) from each.
2.
Disconnect connector (1) from rigger's service light switch (24).
3.
Disconnect two connectors (2 and 3) from dome light (25).
0204 00-3