TM 9-2350-256-20-2
0400 00
Removal
1.
Remove interconnecting tube assemblies (1 and 2) from cylinder control valve (3) and head assemblies (4).
CAUTION
Be sure to remove cylinder control valve (3) from cylinder before any other disconnections are made.
2.
Unscrew and remove two cylinder control valves (3) from fire extinguisher cylinders (5).
3.
Remove six connector head assemblies (4).
4.
Disconnect eight fire extinguisher lines (6).
NOTE
Steps 5 through 11 apply to both the left- and right-side fire extinguisher banks.
5.
Remove retaining bar (7) by removing two screws (8) and two lockwashers (9).