TM 9-2350-256-34
0031 00
Disassembly
CAUTION
Be careful not to damage switch leads when removing handle.
NOTE
Refer to TM 9-2350-256-20 for instructions on further disassembly of the purge pump.
1.
Remove screw (1), lockwasher (2), and clamp (3). Discard lockwasher.
Cut two lockwires (4) and remove two outlet valves (5) and inlet valves (6). Discard lockwires.
2.
Unscrew gland (7) and remove packing (8), two packings (9), and piston and rod assembly (10) from pump housing (11).
3.
Discard packings.
0031 00-2