TM 9--2350--292--20--10018 00--4AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0018 00noyesCONTINUED FROM STEP FGIs continuity present?HnoyesCONTINUED ONNEXT PAGEReplace preheat relay (WP 0664 00).Verify fault is corrected.Repair (WP 0290 00) or replace(WP 0649 00) harness 3W711.Verify fault is corrected.1. Reconnect lead P to preheater relay.2. Disconnect lead 487 at preheater relay.3. Place multimeter red lead to preheater relayterminal and black lead to ground.4. Turn MASTER switch ON(TM 9--2350--292--10).5. Turn PREHEAT switch to MOM ON(TM 9--2350--292--10). Check for voltage.6. Turn MASTER switch OFF.Is 24 V dc present?1. Disconnect harness 3W702 J1 from harness3W711 P1.2. Place multimeter red lead to lead 487 andblack lead to pin D of harness 3W711 P1.3. Check for continuity.noyesIReplace diode (WP 0639 00).Verify fault is corrected.Is 24 V dc present?1. Reconnect harness 3W711 P1 to harness3W702 J1.2. Reconnect lead 487 to preheater relay.3. Disconnect harness 3W711 lead S fromdiode terminal.4. Place multimeter red lead to diode terminaland black lead to ground.5. Turn MASTER switch ON(TM 9--2350--292--10).6. Turn PREHEAT switch to MOM ON(TM 9--2350--292--10). Check for voltage.7. Turn MASTER switch OFF.