TM 9--2350--292--20--1
0007 00--3
QUICK GUIDE TO TROUBLESHOOTING (SYMPTOM/MALFUNCTION) INDEX
-- CONTINUED
0007 00
SYMPTOM
ACTION OR
WP REF
ENGINE -- CONTINUED
ENGINE HAS LOW STALL RPM, DOES NOT DEVELOP FULL POWER, AND HAS
EXCESSIVE SMOKE FROM ONE OR BOTH BANKS OF CYLINDERS.
WP 0047 00
ENGINE HAS EXCESSIVE WHITE SMOKE.
WP 0048 00
ENGINE HAS LOW STALL RPM AND DOES NOT DEVELOP FULL POWER, BUT
EXHAUST SMOKE IS NORMAL.
WP 0049 00
ENGINE RUNS ROUGH OR MISFIRES AND/OR KNOCKS.
WP 0050 00
ENGINE USES EXCESSIVE FUEL.
WP 0051 00
DUST DETECTOR SYSTEM OPERATING. POWER PLANT WARNING LAMP AND
DUST DETECTOR WARNING LAMPS ON AND PRESSURE SWITCH PLUNGERS
ARE VISIBLE.
WP 0052 00
ENGINE HAS LOW POWER AND EXCESSIVE BLACK SMOKE.
WP 0053 00
FUEL/WATER SEPARATOR OPERATES IMPROPERLY.
WP 0054 00
LOW (OR HIGH) ENGINE OIL PRESSURE; OIL TEMPERATURE IS NORMAL.
WP 0055 00
ENGINE USES EXCESSIVE OIL.
WP 0056 00
ENGINE OIL TEMPERATURE IS HIGH.
WP 0057 00
ENGINE OIL BLOWS FROM DIPSTICK TUBE.
WP 0058 00
ENGINE STARTER CRANKS WHEN MASTER SWITCH IS TURNED ON OR ENGINE
STARTER FAILS TO SHUT OFF WHEN ENGINE IS RUNNING.
WP 0059 00
ENGINE CRANKS IN ANY GEAR.
WP 0041 00
ENGINE STARTS BUT FAILS TO KEEP RUNNING.
WP 0041 00
STARTER SPINS BUT DOES NOT ENGAGE. (REPLACE STARTER.)
WP 0240 00
ENGINE STARTER OPERATES WITH LOW BATTERY VOLTAGE. (REPLACE
STARTER LOW VOLTAGE PROTECTION MODULE.)
WP 0241 00
ENGINE OVERSPEEDS
Notify Direct Support
Maintenance
ENHANCED DIAGNOSTICS SYSTEM
SPORT CANNOT COMMUNICATE WITH 1553 BUS CARD.
WP 0061 00
SPORT CANNOT COMMUNICATE WITH REMOTE TERMINAL UNIT.
WP 0062 00
THE NON--VOLATILE CALIBRATION DATA STORED IN REMOTE TERMINAL UNIT
FAILED AN INTERNAL CONSISTENCY CHECK AFTER BEING READ.
WP 0063 00
FAILED TO READ THE NON--VOLATILE CALIBRATION DATA.
WP 0064 00
ALL SENSORS SIGNALS ARE BELOW RANGE OR OPEN.
WP 0065 00
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J1 ARE BELOW VALID
RANGE OR OPEN.
WP 0066 00
ALL SIGNALS AT REMOTE TERMINAL UNIT CONNECTOR J2 ARE BELOW VALID
RANGE OR OPEN.
WP 0067 00
ALL SIGNALS AT CABLE ASSEMBLY 4W504 CONNECTOR J1 ARE BELOW VALID
RANGE OR OPEN.
WP 0068 00
ALL SIGNALS AT REMOTE TERMINAL CONNECTOR J3 ARE BELOW VALID RANGE
OR OPEN.
WP 0069 00