TM 9--2350--292--20--10187 00--410187 00PREVENTIVE MAINTENANCE CHECKS AND SERVICES INCLUDINGLUBRICATION INSTRUCTIONS -- CONTINUEDTABLE 1 PREVENTIVE MAINTENANCE CHECKS AND SERVICESINCLUDING LUBRICATION INSTRUCTIONS, HOURLY OR ON--CONDITION -- CONTINUEDITEMNO.NOT FULLYMISSIONCAPABLEIF:PROCEDURELOCATIONITEM TOCHECK/SERVICEINTERVALHOURLY (H) ORON--CONDITION(OC)INTERIOR8OCHydraulicReservoir FluidChange --ContinuedLUBRICANTS/COMPONENTSREFILLCAPACITYEXPECTED TEMPERATURE*+40°F to --10°F(+4°C to --23°C)Above +32°F(Above 0°C)0°F to --65°F(--17°C to --54°C)Oil: Fire RetardantHydraulic OilMIL--H--4617080 gal(302.80 L)*For Arctic Operation, refer to FM 9--207ALL TEMPERATURES (H--544)j. Fill hydraulic reservoir with proper gradeoil until it reads above DANGER mark onbayonet gauge (7).k. Start engine and operate hydraulicsystem until oil reaches operatingtemperature (TM 9--2350--292--10).l. Shut down engine(TM 9--2350--292--10).m. Remove, wipe clean, then re--insertbayonet gauge (7). Then remove bayonetgauge (7) and verify oil level is at lowerFULL mark with boom down or upper FULLmark with boom up. If required, addadditional oil to bring level to FULL mark.n. Install hydraulic fill cap (5) and bayonetgauge (7).57BOOM UP FULL HOT BOOM DOWN DANGER