TM 9--2350--292--20--1AUXILIARY POWER UNIT FAILS TO CRANK -- CONTINUED0009 001. Reconnect lead 3W706 lead 66 to starter relayand generator terminal B.2. Disconnect lead S from generator terminal A.3. Turn MASTER switch ON and hold PREHEATand START switches in ON position(TM 9--2350--292--10).4. Place multimeter red lead on lead S leadconnector and black lead to ground. Check forvoltage.5. Turn MASTER switch OFF(TM 9--2350--292--10).CONTINUEDFROMSTEPADIs 24 V dc present?AEnoyesRepair (WP 0290 00) or replace(WP 0648 00) lead S lead frompreheat relay to generator terminalA. Verify fault is corrected.Is continuity present?1. Reconnect lead S to terminal A.2. Disconnect ground wire from generatorterminal E.3. Place one multimeter lead on end of groundwire and other lead to vehicle ground. Checkfor continuity.AFnoyesReplace generator (WP0633 00). Verify fault iscorrected.Repair (WP 0290 00) orreplace (WP 0652 00)ground wire. Verify faultis corrected.END OF TASK0009 00--13/14 blank
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business