TM 9--2350--292--20--2
0684 00--13
HYDRAULIC CONTROL VALVE MANIFOLD ASSEMBLY SWITCH,
TRANSDUCERS AND ASSOCIATED PARTS REPLACEMENT -- CONTINUED
0684 00
Installation
NOTE
Apply a thin even coat of clean lubricant to all preformed
packings prior to installation.
1. Install new preformed packings (71 and 72) on straight swivel adapter (69) and elbow (70).
2. Install elbow (70) in hydraulic control valve manifold assembly (8) port P TEST.
3. Install straight swivel adapter (69) on transducer 4MT523 (68) then install transducer 4MT523 (68) with straight
swivel adapter (69) on elbow (70).
4. Install wiring harness 4W506 connector P2 (67) on transducer 4MT523 (68).
NOTE:
HYDRAULIC CONTROL
VALVE MANIFOLD
SHIELDS, HOSES,
AND FITTINGS
REMOVED FOR CLARITY
67
68
71
69
70
72
8