TM 9--2350--292--20--2AUXILIARY POWER UNIT INTAKE AIR CLEANER ASSEMBLYREPLACEMENT -- CONTINUED0608 00Installation.NOTEPosition housing assembly base to permit access to bothlatches.1. Install housing assembly base (11) and new gasket (12) with four screws (9) and four new lockwashers (10).2. Clean inside of housing assembly cover (2) and housing assembly base (11) with clean wiping rag.3. Install new filter element (6) in housing assembly base (11) with screw (3), washer (4) and plate (5). Hand tightenscrew (3) until snug.4. Position housing assembly cover (2) on housing assembly base (11) and secure with two latches (1).5. Slide hose (8) over housing assembly cover (2).6. Position clamp (7) over hose (8), tighten hose clamp (7).WARNING7. If decal was removed, clean area of decal (13) with dry--cleaning solvent. Ensure area is smooth, clean and dry.8. Apply new decal (13) in the same position where the old decal (13) was removed.Figure 33634562111210978131END OF TASK0608 00--3/4 blank