TM 9--2350--292--20--1
0254 00--2
STE--ICE RESISTOR BOX AND BRACKET REPLACEMENT -- CONTINUED
0254 00
Installation
NOTE
Make sure screws are tightened sufficiently to cause ex-
ternal tooth lockwasher to cut through paint to make elec-
trical contact.
1. Install bracket (12) with four screws (13) and four new lockwashers (14).
2. Install wiring harness 4W800 DCA connector J1 (7) and cap (6) on bracket (12) with four screws (8), four flat
washers (9), four new lockwashers (10) and four nuts (11).
3. Install cap (6) on wiring harness 4W800 DCA connector J1 (7).
NOTE
Use one external lockwasher next to head of screws and
one external tooth lockwasher next to nut.
4. Install resistor box (2) with four screws (3), eight new lockwashers (4) and four nuts (5).
5. Connect wiring harness 4W800 connector P2 (1) to resistor box (2) receptacle.
Figure 71
1
2
3
4
4
12
5
9
10
11
7
6
8
14
13
NOTE
FOLLOW--ON MAINTENANCE:
Install air purifier control unit enclosure assembly and
bracket, if removed (WP 0707 00)
Connect battery power (WP 0256 00)