TM 9--2350--292--20--1
0084 00--2
GENERATOR OUT INDICATOR DOES NOT LIGHT WHEN GENERATOR
SWITCH IS PLACED IN ON POSITION -- CONTINUED
0084 00
CONTINUED FROM STEP A
no
yes
Repair (WP 0290 00) or
replace (WP 0244 00)
lead 450A. Verify fault is
corrected.
B
1. Remove accessory panel (WP 0244 00) and
disconnect lead 450A from CB5.
2. Place one multimeter lead on accessory panel
receptacle J3 pin H and other lead in lead 450A
CB5 connector. Check for continuity.
Is continuity present?
C 1. Disconnect lead 38--138--450A from other side
of CB5.
2. Place one multimeter lead on each CB5
connector pin. Check for continuity.
Is continuity present?
no
yes
Replace CB5 (WP 0290 00).
Verify fault is corrected.
no
yes
Repair (WP 0290 00) or
replace (WP 0244 00)
lead 38--138--450A from
CB5 to switch S4. Verify
fault is corrected.
D
1. Reconnect lead 38--138--450A to CB5.
2. Disconnect lead 450A from switch S4.
3. Place one multimeter lead in lead 38--138--450A
connector and other lead in lead 450A switch S4
connector. Check for continuity.
Is continuity present?
CONTINUED ON NEXT PAGE