TM 1-1680-320-13&P
0021 00
WARNING
Visually verify that dowel pin properly aligns with motor dowel pin receiver.
5. Install motor (6) onto adapter plate (11) and dowel pin.
6. Torque coupling (8) to 50-55 in. lbs.
7. Tap coupling (8) with rubber mallet to ensure it is properly seated.
8. Retorque coupling (8) to 50-55 in. lbs.
9. Install motor airduct (4) to motor mount flange (11) using bolt (5).
10. Torque bolt to 24-27 in. lbs.
11. Install boot (1) to motor airduct (4) and control panel fan blower assembly using bands (3) and clips (2).
End of Work Package
0021 00-4