TM 9-2350-238-34-12-18. REPLACING CABLE TERMINALS AND SHELL CONNECTORS.T E R M I N A L - T Y P E C A B L E C O N N E C T O RS1234Strip cable insulation equal to depth ofterminal well (1).Slide insulator (2) over cable (3).Insert cable (3) into terminal well (1) andc r i m p.Slide insulator (2) over crimped endo f t e r m i n a l ( 4 ) .M A L E C A B L E S H E L L C O N N E C T O R 1234Strip cable insulation equal to depth off e r r u l e w e l l ( l ).Slide shell assembly (2) over cable (3).Insert cable (3) into ferrule well (1) andc r i m p .Place C-washer (4) over cable (3) at crimpedjunction and slide shell assembly (2) overC-washer (4) and ferrule (5).F E M A L E C A B L E S H E L L C O N N E C T OR( W I T H W A S H E R)1234Strip cable insulation approximately 1/8 in.( 0 . 3 1 8 c m ).Slide shell assembly (1) and washer (2) overc a b l e ( 3 ) .Place cable (3) in cylindrical end of terminal( 4 ) a n d c r i m p.Slide shell assembly (1) and washer (2) overt e r m i n a l ( 4 ) .2 - 27